Installation
Operation &
Maintenance
What To Do If You Smell Gas:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call the re department.
Corner
Gas Fireplace
M40DV-CR/CL
(MH)
Installer: Leave this manual
with the appliance.
Consumer: Leave this man-
ual for future reference.
Check local codes and read all
instructions prior to installation.
®
C US
Safety Notice:
Glass doors on gas fireplaces are
extremely hot while the fireplaces is on
and remain hot even after the fireplace
has been turned off. Safety screens
are available and can reduce the risks
of severe burns. Please keep children
away from the fireplace at all times.
WARNING!
Improper installation, adjustment,
alteration, service or maintenance
can cause injury or property
damage. Refer to this manual. For
assistance or additional information
consult a qualied installer, service
agency or the gas supplier.
For Your Safety:
Do not store or use gaso-
line or other ammable
vapors and liquids in
the vicinity of this or any
other appliance.
Przeglądanie stron 0
1 2 3 4 5 6 ... 25 26

Podsumowanie treści

Strona 1 - M40DV-CR/CL

InstallationOperation &MaintenanceWhat To Do If You Smell Gas:• Do not try to light any appliance.• Do not touch any electrical switch; do n

Strona 2 - Table Of Contents

P/N XG0206Page 10M40DV-CR/CL Corner Gas FireplaceTop Vent Venting RequirementsBefore you install any venting, you must determine whether the venting r

Strona 3 - Introduction

Page 11P/N XG0206M40DV-CR/CL Corner Gas FireplaceInstallationFigure 14b. Retracted Installation.Figure 14a. Extended installation.Figure 13. Short Hor

Strona 4

P/N XG0206Page 12M40DV-CR/CL Corner Gas FireplaceInstallationInstallation Of Vertical Vent DVVertical Terminations must be installed: • minimum 2

Strona 5

Page 13P/N XG0206M40DV-CR/CL Corner Gas FireplaceFinishing Around the FireplaceCombustible mantels and mouldings may be safely installed over the top

Strona 6

P/N XG0206Page 14M40DV-CR/CL Corner Gas FireplaceInstallationWiringGas Control and Pilot WiringFigure 21. Wiring for the M40DV-CR/CL-I with Honeywell

Strona 7

Page 15P/N XG0206M40DV-CR/CL Corner Gas FireplaceInstallationOperationLighting InstructionsSee Pages 15-16. Burner AdjustmentThe M40DV-CR/CL is equipp

Strona 8

P/N XG0206Page 16M40DV-CR/CL Corner Gas FireplaceFor Your Safety - READ BEFORE LIGHTING:WARNING: If you do not follow these instructions exactly, a 

Strona 9

Page 17P/N XG0206M40DV-CR/CL Corner Gas FireplaceFor Your Safety - READ BEFORE LIGHTING:To Turn Off Gas To Appliance:Lighting Instructions:WARNING:

Strona 10 - Installation

P/N XG0206Page 18M40DV-CR/CL Corner Gas Fireplacewith Proame SIT Electronic IgnitionOperation - Model M40DV-CR/CL-F with American Flame Electronic

Strona 11

Page 19P/N XG0206M40DV-CR/CL Corner Gas FireplaceMaintenanceGeneral Have the fireplace installation inspected yearly, including a visual check of the

Strona 12

P/N XG0206Page 2M40DV-CR/CL Corner Gas FireplaceWarning: Read this manual before installing, operating or troubleshooting this appliance. Please retai

Strona 13

P/N XG0206Page 20M40DV-CR/CL Corner Gas FireplaceMaintenanceTroubleshooting If your fireplace still does not operate correctly, consult your dealer or

Strona 14 - M40DV-CR/CL-I

Page 21P/N XG0206M40DV-CR/CL Corner Gas FireplaceCanadian Heating Products Inc. and/or Montigo DelRay Corp. reserves the right to make changes at any

Strona 15 - Installing the Ember Material

P/N XG0206Page 22M40DV-CR/CL Corner Gas FireplaceAppendix A - Termination LocationsA = clearance to the termination frame above grade, veranda, porch

Strona 16 - Gas Control Knob

Page 23P/N XG0206M40DV-CR/CL Corner Gas FireplaceAppendix B - M40DV-CR/CL-MH Mobile HomeThis appliance may be installed as an OEM installa-tion in a m

Strona 17 - Lighting Instructions:

P/N XG0206Page 24M40DV-CR/CL Corner Gas Fireplace Amendment (Gas Fireplace / Equipment sold in the Sta

Strona 18 - M40DV-CR/CL-F

Page 25P/N XG0206M40DV-CR/CL Corner Gas FireplaceNotes:

Strona 19 - GLASS DOOR

Canadian Heating Products Inc.Langley, BC V4W 4A1Montigo Del Ray Corp.Ferndale, WA 98248XG0206 - 092508

Strona 20 - Maintenance

Page 3P/N XG0206M40DV-CR/CL Corner Gas FireplaceIntroductionThe M40DV-CR/CL is a direct-vented, 2-sided Gas Fireplace with an adjustable burner. It ca

Strona 21 - Warranty

P/N XG0206Page 4M40DV-CR/CL Corner Gas FireplaceInstallationInstalling The Fireplace ShellThe fireplace may be installed in any location that maintains

Strona 22 - P/N XG0206

Page 5P/N XG0206M40DV-CR/CL Corner Gas FireplaceInstalling The Gas LineThe gas line must be installed before finishing the M40DV-CR/CL fire-place. Natur

Strona 23 - Conversion Kits

P/N XG0206Page 6M40DV-CR/CL Corner Gas FireplaceInstallationInstalling Heat Guards over Terminations 1. Ensure that the two long mounting brackets ar

Strona 24

Page 7P/N XG0206M40DV-CR/CL Corner Gas FireplaceVenting RequirementsIf your installation requires more than 12" of horizontal venting, some verti